Below is a listing of the main VFL options and accessories. If your required option or accessory is not listed, look no further than your local BAC representative.

Plume abatement coil
A finned discharge coil is installed in your cooling tower discharge and piped in series with the wet coil. This reduces or eliminates plumes and extends the dry cooling capacity. Read more

Sound attenuation
Reducing noise at air intake and discharge points brings us closer to silent cooling equipment.
- The sound reductions obtained by HS sound attenuation are perfect for residential sound requirements.
- Heavy noise reductions can be achieved with HD sound attenuation, making it ideal for rural requirements.

Baltiguard drive system
With this, operate your system like a dual-speed motor, but with standby reserve capacity to cope with any failure. Read more

Basin heater package
Thanks to our factory-installed heaters, the water stays at 4°C and never freezes, even during tower downtime and however cold it gets outside. Read more

Nitrogen filling of coil
Charge the cooling coil with nitrogen for anti-corrosion protection during long shipment periods (ocean freight) or on-site storage. Read more

Remote sump connection
The best way to prevent a sump freezing is to use the auxiliary remote variety within a heated area. Shutting off the circulating pump allows all the water in the water distribution, as well as that in suspension and the sump to drain freely to the auxiliary sump. Read more

Electric water level control package
For perfectly precise water level control, replace the standard mechanical valve with our electrical water level controller. Read more

Discharge hood
Discharge hoods reduce the risk of re-circulation in tight enclosures by increasing discharge air velocity, and can be used to elevate the unit discharge above adjacent walls to comply with layout guidelines. Read more

Positive closure dampers
Use positive closure dampers (PCD) to minimize the heatloss due to convection by preventing air flow through equipment that is shut down. Read more

Clean out port
Clean out port makes it easy to eliminate silt and sludge from the cooling tower basin when cleaning and flushing the sump. Read more

Pump relocation
Move the pump to the connection side and make it more accessible when using sound attenuation at the fan side. Read more

Filter
Separators and media filters efficiently remove suspended solids in the recirculating water, reducing system cleaning costs and optimizing water treatment results. Filtration helps you keep the recirculating water clean. Read more

Sump sweeper piping
Sump sweeper piping prevents sediment collecting in the cold water basin of the unit. A complete piping system, including nozzles, is installed in the basin of the tower for connection to side stream filtration equipment. Read more

Water treatment equipment
Devices to control water treatment are needed to ensure proper cooling tower water care. Not only does this help protect the components and fill pack, controlling corrosion, scaling and fouling, it also avoids the proliferation of harmful bacteria, including legionella, in the recirculating water. Read more